The Hotel Fire-Rated Door is configured here for Southeast Asia. The figures below are the published catalogue specification of the series; the market section covers what projects in Southeast Asia add to it. Send the opening schedule and the glazing you want, and the quotation comes back with the dimensional pack.

Open wooden hotel fire door looking through to a suite interior with dark joinery, design rendering

Hotel Fire-Rated Door · Southeast Asia

Hotel Fire-Rated Door

The hotel series is a single-leaf fire door built for guest floors, tested and marked at 20, 45, 60 and 90 minutes. The complete configuration, glass options and finish list are on the door series page.

Door type
Single-leaf fire door, per catalogue section drawings
Fire rating
20 / 45 / 60 / 90 min, catalogue test labels
Leaf
Wooden leaf · laminate / HPL / wooden veneer
Frame
Timber frame standard · steel frame with wooden leaf on one model
Core
B1 flame-retardant board with a honeycomb core
Certification
AS 1905.1:2015 · AS 1530.4:2014 · EN 1634-1:2014+A1:2018 · CAN/ULCS104 · UL Listed
Ironmongery
Concealed closer · fire-certified viewer · fire-certified electronic lock · hinge · latch · lever
Sealing
Intumescent fireproof strip with an automatic door bottom
Application
Hotel guest rooms · apartment entries

HOTEL FIRE-RATED DOOR · 01
HOTEL FIRE-RATED DOOR · 03

Engineering

Single-leaf fire doorThe series is drawn as a single-leaf fire door for hotel and apartment openings, with the leaf, frame and ironmongery specified as one set.

B1 flame-retardant leaf with a honeycomb coreBehind the face the catalogue describes a B1 flame-retardant board over a honeycomb core, a light sandwich that keeps a wide leaf straight.

Fire-certified hardwareA concealed closer, a fire-certified viewer and a fire-certified electronic lock sit on the standard schedule with heavy-duty hinges and a latch.

Accredited fire certificationCompliance is listed to AS 1905.1:2015, AS 1530.4:2014, EN 1634-1:2014+A1:2018 and CAN/ULCS104 with UL listing and the Intertek, CE, BS, IAS, FSC and HKAS marks.

Heat, humidity and salt air

Southeast Asian sites push three things at aluminium: sustained heat, high humidity and, on the coast, salt spray. The finish carries the corrosion load, which is why fluorocarbon and powder lines are the standard shortlist for coastal work, with EPDM sealing and open self-cleaning drainage handling the moisture inside the section.

Glazing is specified per project: single glass where cooling load is the driver, insulating units where comfort is. The build-up comes back on the quotation against your climate and the budget line for the envelope.

Ports and logistics for the region

The main ports in the region are covered by standard export packing: modules travel upright, edge-protected, in 20 ft or 40 ft containers, and the loading plan for your opening mix ships with the quotation.

Transit times vary by origin port and destination, so they are confirmed per shipment rather than quoted from a fixed table.

FAQ

Frequently asked

Which finishes hold up in coastal Southeast Asia?

Fluorocarbon and anodised lines are the standard shortlist against salt spray. RAL matching and two-tone exterior/interior combinations are available on request.

Do you ship to the Philippines and Malaysia?

Yes. Modules ship to ports across the region in export-standard containers, and the loading plan with the transit confirmation comes with the quotation.

What is the hotel fire-rated door series?

It is a single-leaf wooden fire door for hotel and apartment openings, marked at 20, 45, 60 and 90 minutes and supplied as a leaf, frame and hardware set.

Which fire ratings are available?

The catalogue marks the series at 20, 45, 60 and 90 minutes across the frame and the leaf. Values are catalogue fire ratings, quoted against the opening.

Send your opening schedule

Series, glazing and finish come back as one quotation for Southeast Asia, with the full dimensional pack on PDF and CAD on request.